General specifications:<:/b>
|
|
Power Source:
|
120 V AC, 60 Hz
|
Power Consumption:
|
60 W
|
Ambient Operating Temperature:
|
�10 �C to +50 �C {14 �F to 122 �F}*1
|
|
In the constant operation
|
Ambient Operating Humidity:
|
Less than 90 %
|
Video Input Board:
|
x 1
|
Camera Input (CAMERA IN 1 to 32):
|
1 V [P-P]/75 Ω (BNC x 32), composite video signal
|
|
0.5 V [P-P]/75 Ω data signal and 2.5 V [P-P]/75 Ω vertical timing pulse multi-
|
|
plexed
|
Video Output (VIDEO OUT 1 to 4):
|
1 V [P-P]/75 Ω (25-pin D-sub connector x 4)*2, active loop-thru output
|
Alarm Input (ALARM IN):
|
N.O. (Normally Open contact) or N.C. (Normally Close contact) selectable x 32
|
|
(37-pin D-sub connector)
|
RS-485 (Camera) Port:
|
6-conductor modular jack x 4 (2-wire or 4-wire communication, With termination
|
|
switches (MODE 1 to 4))
|
Extension Port (EXTENSION IN 2, 3):
|
37-pin D-sub connector x 2
|
Video Output Board:
|
x 1
|
Monitor Output (MONITOR OUT 1 to 16):
|
1 V [P-P]/75 Ω (BNC x 16)
|
Data Port (DATA 1 to 4)
|
|
DATA 1, 2:
|
Terminal Mode (TMNL)/PS�Data (PS�DATA) selectable
|
DATA 3, 4:
|
Terminal Mode (TMNL)/Digital disk recorder (HDR) selectable
|
|
6-conductor modular jack x 4 (With termination switches (MODE 1 to 4))
|
Alarm Output (ALARM OUT 1, 2)
|
|
Alarm Output:
|
Open collector output x 32, Max. 24 V DC, 100 mA
|
Alarm Recover Output:
|
Non-voltage make contact input x 16
|
Time Adjust Input*3:
|
Non-voltage make contact input x 1
|
Time Adjust Output*3:
|
Open collector output x 32, Max. 24 V DC, 100 mA
|
Extension Port (EXTENSION 1 IN, OUT)*3:
|
6-conductor modular jack x 2 (With a termination switch (TERM: ON, OFF))
|
|
VS Input*3: 1 V [P-P]/75 Ω (VS IN)
|
|
VS Output*3 (VS OUT (THRU)): VS loop-thru output
|
|
(VS OUT): 1 V {P-P}/75 Ω (VS)
|
Serial Port*:
|
9-pin D-sub connector x 2
|
Dimensions:
|
420 mm (W) X 265 mm (H) X 372 mm (D)
|
|
{16-9/16" (W) X 10-2/5" (H) X 14-3/5" (D)} (excluding rubber feet and projections)
|
Weight:
|
19.0 kg (42 lbs.)
|